What kind of images are produced in an sem




















The resolving power of the microscope was not only limited by the number and quality of the lenses but also by the wavelength of the light used for illumination. White light has wavelengths from to nanometers nm. The average wavelength is nm which results in a theoretical limit of resolution not visibility of the light microscope in white light of about — nm. The figure below shows two points at the limits of detection and the two individual spots can still be distinguished.

The right image shows the two points so close together that the central spots overlap. The electron microscope was developed when the wavelength became the limiting factor in light microscopes.

Electrons have much shorter wavelengths, enabling better resolution. As dimensions are shrinking for materials and devices, many structures can no longer be characterized by light microscopy.

For example, to determine the integrity of a nanofiber layer for filtration, as shown here, electron microscopy is required to characterize the sample. The main SEM components include:. Electrons are produced at the top of the column, accelerated down and passed through a combination of lenses and apertures to produce a focused beam of electrons which hits the surface of the sample. This distance is called the resolving power of the lens, which can magnify the distance many times over.

However, a light microscope has a resolving power of about x, as it is limited by the wavelength of the light as well as the quality and number of lenses used. However, electron microscopes provide a shorter wavelength, which creates a better resolution. The spatial resolution is dependent on the size of the electron spot. Unlike conventional image forming cameras film or CCD array , SEM uses an electron beam to rapidly scan over a specimen sample to yield an image. The resolution of SEM is normally around 10 nanometres nm.

The maximum resolution for a scanning electron microscope image depends on factors such as the interaction volume of the beam and the electron spot size.

SEMs can achieve a high resolution of below 1 nanometre nm , although they cannot provide atomic resolutions. Most modern SEMS provide a resolution of nm, while smaller desktop versions offer a resolution of 20 nm or more.

TWI carries out electron microscopy on behalf of our Industrial Members across a variety of industry sectors. TWI has a well-equipped microscopy and metallography suite with several highly experienced members of staff. Goldstein, J. Reimer, L.

Springer, p. Egerton, R. Springer, Clarke, A. CRC Press electronic resource. Argast, Anne and Tennis, Clarence F. Geoscience Education, v 52 1, p. Material on this page is offered under a Creative Commons license unless otherwise noted below. Show terms of use for text on this page ». Show terms of use for media on this page ». Your Account. Reuse Citing and Terms of Use Material on this page is offered under a Creative Commons license unless otherwise noted below.

Show terms of use for text on this page » Page Text A standard license applies as described above. Click More Information below. Images image details Provenance No information about the origin of this particular item is recorded. Please contact SERC serc carleton. Reuse No information about limits on reusing this item have been recorded.